3002

From NDWiki
Revision as of 23:56, 20 October 2008 by Gandalf (talk | contribs) (Initial page, copy from Rogers wiki)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search

3002 is the ND-100 CPU board. It contains the CPU, bus arbitration logic, memory control and other subsystems. It also have the Real time clock and the I/O for the serial console.

There are schematics of the CPU in the NORD-100 Input Output System manual (ND-06.016.01).

Description of MOPC

MOPC is the name of the Microprogrammed OPerators Communication, a program stored in the micro code of the CPU. It can be used for low level testing of the hardware. Whenever the MOPC is active it is communicating via the console connected to the current loop connection on the CPU card. MOPC contains functions for examination of the memory, dumping registers, changing content in registers or memory, controlling breakpoints, bootstrap loading and other things.

Main article : MOPC

I/O devices on the CPU board

The CPU board is equipped with two I/O devices, the real time clock and the system console.

RTC

RTC is the Real-Time Clock. It is a system that could generate interrupts on a 20 ms basis.

RTC IOX register map

IOX 10:

Returns 0 in A register, no other effect.

IOX 11:

Clears real time counter. This instruction will cause the
next clock pulse to occur exactly 20 ms later.
If executed often enough it will stop the real-time counter
from incrementing. This could affect operators communicating
via the console.

IOX 12:

Read real-time clock status.
 Bit 0=1 : An interrupt will be generated at the next clock pulse.
 Bit 3=1 : A clock pulse has occurred.
 Bit 1-2 and 4-15 is always zero.

IOX 13:

Set real-time clock status.
 Bit 0=1 : Enable interrupt on next clock pulse.
 Bit 13=1 : Set bit 3 to zero in the real-time clock status word.

Console

The console could be disabled by removing a strap.

Console IOX register map

IOX 300:

Read input data (according to input control word setting).
The last character is transferred to the A register. The
data available signal is reset if MOPC is not active.

IOX 301:

No operation.

IOX 302:

Read input status
 Bit 0=1 : Interrupt on "Data available" enabled.
 Bit 3=1 : Data available. (Never set when MOPC is active.)
 Bit 4=1 : 
 Bit 5=1 : 
 Bit 6=1 : 
 Bit 7=1 : 

IOX 303:

Set input control
 Bit 0=1 : Enable interrupt on "Data available".
 Bit 11=0, bit 12=0 : 8 bit data.
 Bit 11=1, bit 12=0 : 7 bit data.
 Bit 11=0, bit 12=1 : 6 bit data.
 Bit 11=1, bit 12=1 : 5 bit data.
 Bit 13=0 : 2 stop bits (1.5 stop bits for 5 bit data).
 Bit 13=1 : 1 stop bit.
 Bit 14=0 : No parity.
 Bit 14=1 : Parity bit added to data.

IOX 304:

Returns 0 in A register, no other effect.

IOX 305:

Write output data (according to input control word setting).

IOX 306:

Read output status.
 Bit 0=1 : Interrupt on "Ready for transfer" is enabled.
 Bit 3=1 : Ready for transfer.
 Bit 1-2 and 4-5 are always zero.
   (should probable be 1-2 and 4-15, an error in the documentation)

IOX 307:

Set output control.
 Bit 0=1 : Enable interrupt on "Ready to transfer"

Notes :

There is some strange wordings in the manual but I guess that there is
no interrupts or reset of the data ready status bit when MOPC is running.

Reference

Ref. ND-06.015.02 ND-100 Functional Description, 1985