3026

From NDWiki
Jump to navigation Jump to search
The printable version is no longer supported and may have rendering errors. Please update your browser bookmarks and please use the default browser print function instead.

3026 is a GPIB[1] controller.

Introduction

What does it do?

Switches and indicators

  • Thumbwheel 1 - device-number switch
    • 1: device 0, dev.no (octal) 140000, Ident code (octal) 140000
    • 2: device 1, dev.no (octal) 140010, Ident code (octal) 140001
    • 3: device 0, dev.no (octal) 141400, Ident code (octal) 140140
    • 4: device 0, dev.no (octal) 141410, Ident code (octal) 140141
    • 5: device 0, dev.no (octal) 141420, Ident code (octal) 140142
    • 6: device 0, dev.no (octal) 141430, Ident code (octal) 140143
    • 7: device 0, dev.no (octal) 141440, Ident code (octal) 140144
    • 8: device 0, dev.no (octal) 141450, Ident code (octal) 140145
  • LED 6 (yellow) : SYC - system-controller switch in ON position
  • LED 5 (yellow) : REMOK - REMote OK, remote option in fumction
  • LED 4 (yellow) : DMACT - DMA ACTive
  • LED 3 (red)  : ERROR - Z80 microprogram has detected an error
  • LED 2 (green)  : FIFO - First-In-First-Out register is empty
  • LED 1 (green)  : RFT - Ready for transfer
  • System-controller switch
    • switch ON: ND-100 is system controller
    • switch OFF: ND-100 is NOT system controller

Connectors

The A and B connectors are used for I/O, the C connector is used for the ND-100 Bus.

I/O Devices on the card

none?

ECO

Here is a list of known ECO's (Engineering Change Order) for this card.

  • ECO 100-755 - Only valid with remote-box. May loose data. Status: REMOTE BOX NOT CONNECTED.[2]
  • ECO 100-784 - May give various errors as ERROR 70, 72, 73[2]

References

  1. Wikipedia:GPIB
  2. 2.0 2.1 sintran.com, Norsk Data library, ECO [1]