<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://www.ndwiki.org/index.php?action=history&amp;feed=atom&amp;title=3039</id>
	<title>3039 - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://www.ndwiki.org/index.php?action=history&amp;feed=atom&amp;title=3039"/>
	<link rel="alternate" type="text/html" href="https://www.ndwiki.org/index.php?title=3039&amp;action=history"/>
	<updated>2026-05-06T07:55:06Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.43.8</generator>
	<entry>
		<id>https://www.ndwiki.org/index.php?title=3039&amp;diff=4555&amp;oldid=prev</id>
		<title>Tingo: created 3039 page</title>
		<link rel="alternate" type="text/html" href="https://www.ndwiki.org/index.php?title=3039&amp;diff=4555&amp;oldid=prev"/>
		<updated>2018-01-14T17:48:26Z</updated>

		<summary type="html">&lt;p&gt;created 3039 page&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;&amp;#039;&amp;#039;&amp;#039;3039&amp;#039;&amp;#039;&amp;#039; is the ND-100 bus controller.&lt;br /&gt;
{{Stub}}&lt;br /&gt;
==Introduction==&lt;br /&gt;
What does it do?&lt;br /&gt;
&lt;br /&gt;
==Switches and indicators==&lt;br /&gt;
* short timeout indicator (lit if short timeout is selected)&lt;br /&gt;
* timeout selector&lt;br /&gt;
** short timeout (2 mS)&lt;br /&gt;
** long timeout (8 mS)&lt;br /&gt;
A BUSC controlling a memory bank should have a short timeout. A BUSC controlling an I/O bus should have a long timeout.&lt;br /&gt;
* ADOK - Address OK indicates which bank the last master-bus cycle was accessing. It is reset by start of next master-bus memory cycle.&lt;br /&gt;
* extended device-number switch&lt;br /&gt;
* interleave selector&lt;br /&gt;
* device number&lt;br /&gt;
* Base-setting display&lt;br /&gt;
* Upper-limit display&lt;br /&gt;
* Lower-limit display&lt;br /&gt;
* Base address switches&lt;br /&gt;
* Upper limit switches&lt;br /&gt;
* Lower limit switches&lt;br /&gt;
For Base, Upper and Lower limit switches: the most-significant switch is topmost, and the least-significant switch is closest to the bottom of the card. The address area for a bus controller is decided by the setting of lower and upper address limit. The limit-address increments are 64K units.&lt;br /&gt;
&lt;br /&gt;
==Connectors==&lt;br /&gt;
The A and B connectors are used for I/O, the C connector is used for the [[ND-100 Bus]].&lt;br /&gt;
&lt;br /&gt;
==I/O Devices on the card==&lt;br /&gt;
none?&lt;br /&gt;
&lt;br /&gt;
==References==&lt;br /&gt;
*{{ND-doc|30.008.3 EN}}, page 221&lt;br /&gt;