@DEFINE-SPOOLING-CONDITIONS <peripheral file name>, <PRINTING NAME OF SPOOLING FILES?>, <STOP AND WAIT FOR START-PRINT BEFORE PRINTING FILE?>, <number of lines per page>

Define conditions under which spooling on a peripheral must operate.

<peripheral file name>
the spooling device.
<PRINTING NAME OF SPOOLING FILES?>
YES = the file names will be printed on the error device when printing starts. Otherwise, NO (default = NO).
<STOP AND WAIT FOR START-PRINT BEFORE PRINTING FILE?>
YES = automatic @STOP-PRINT between every printing of a file (see @DEFINE-SPOOLING-FILE-MESSAGE). Otherwise, NO (can be YES only if <PRINTING NAME OF SPOOLING FILES?> = YES. Default = NO).
<number of lines per page>
number of lines per page as used by the command @FORWARD-SPACE-PRINT and @BACKSPACE-PRINT (default = 68).


Rules:

  1. Permitted only for user SYSTEM.

Example:

@DEFINE-SPOOLING-CONDITIONS L-P, NO, NO,

Spooling conditions are defined on the peripheral file L-P. Files are output without interruption.

Related commands

@DEFINE-SPOOLING-FILE-MESSAGE

References

Norsk Data Document ND–60.128.01 SINTRAN III REFERENCE MANUAL (printed June 1980), page 1-50