87 extensions
The ND-5000 '87 extension is a set of 25 instructions that the ND-500 Reference Manual (ND-05.009.4, June 1987 edition) labels ('87 extension). They came with the ND-5000. The manual says they also run on ND-500/1 and ND-500/2 CPUs. The ND-5000 otherwise uses the same instructions as the ND-500.
Counts
| Instructions | Opcode entries | Distinct opcodes | |
|---|---|---|---|
| ND-500 base (not labelled '87) | 229 | 1063 | 1033 |
| '87 extension, already in the emulator's instruction data | 23 | 34 | 34 |
| All of the emulator's instruction data today | 252 | 1097 | 1067 |
| '87 extension, according to the manual | 25 | not counted | 46 |
| ND-5000 total, according to the manual (base + all '87) | 254 | not counted | 1079 |
Opcode entries are the entries of the emulator's instruction data (what the emulator's tables call variants); distinct opcodes count each opcode value once, because some entries share an opcode. The base row assumes the instruction data holds every other instruction of the manual; that was not checked. Counts as of 2 November 2026.
The 25 instructions
| Manual section | Instruction | What it does | Manual page | Opcodes (manual) | Privileged |
|---|---|---|---|---|---|
| 10.36 | AMODB | Integer modulo | 158 | 0xFFBC to 0xFFC7 | not stated |
| 10.37 | ENTIER | SIMULA Entier function | 159 | 0xFDC7, 0xFDC8 | not stated |
| 15.15 | PLCCN | Convert PLANC descriptor to ND-500 descriptor | 268 | 0xFFFD | not stated |
| 15.16 | NCPLC | Convert ND-500 descriptor to PLANC descriptor | 269 | 0xFFFE | not stated |
| 15.17 | CLINIT | Initialize local clock | 270 | 0xFF1E | yes |
| 15.18 | CLREAD | Read local clock | 271 | 0xFF1F | not stated |
| 16.11 | DDIRT | Dump 'Dirty' | 285 | 0xFFFA | not stated |
| 16.26.1 | RHOLE | Read from NUCLEUS hole | 301 | 0xFE9E | not stated |
| 16.26.2 | WHOLE | Write to NUCLEUS hole | 302 | 0xFE9D | not stated |
| 16.26.3 | SEND | Send to port | 303 | 0xB6 | not stated |
| 16.26.4 | RECVE | Receive from port | 304 | 0xB7 | not stated |
| 16.27.1 | SREGBL | Save register block | 307 | 0xFFF7 | not stated |
| 16.27.2 | LREGBL | Load register block | 308 | 0xFFF6 | not stated (see Notes) |
| 16.27.3 | SCNTXT | Save context block | 309 | 0xFFF9 | yes |
| 16.27.4 | LCNTXT | Load context block | 310 | 0xFFF8 | yes |
| 16.28 | REXT | Read from device external to CPU | 311 | 0xFFE8, 0xFFE9, 0xFFEA, 0xFFEB | yes |
| 16.29 | WEXT | Write to device external to CPU | 312 | 0xFFEC, 0xFFED, 0xFFEE, 0xFFEF | yes |
| 16.30 | TOSSP | Special load of TOS | 313 | 0xFE9F | not stated |
| 16.31 | RPHS | Read from physical segment | 314 | 0xFFF5 | yes |
| 16.32 | WPHS | Write to physical segment | 315 | 0xFFF4 | yes |
| 16.33 | CAD | Load CAD | 316 | 0xFDBA | yes |
| 16.34 | JUMPS | Call supervisor | 317 | 0xB9 | not stated |
| 16.35 | SVERS | Store microprogram version | 318 | 0xFFFB | not stated |
| 16.36 | SCPUNO | Store CPU number | 319 | 0xFFFC | not stated |
| 16.37 | PHYLADR | Get physical address | 320 | 0xFFF0, 0xFFF1, 0xFFF2, 0xFFF3 | not stated |
Formats
As printed in the manual. In /r/W the letter after the first slash is the access (r = read, w = write) and the last is the data type (W = word). See the manual's section on operand notation.
- AMODB:
tn AMODB <operand1/r/t>,<operand2/r/t> - ENTIER:
t ENTIER <source/r/t1>,<destination/w/w> - PLCCN:
W PLCCN <source/r/W>,<destination/w/W> - NCPLC:
W NCPLC <source/r/W>,<destination/w/W> - CLINIT: no format line in the manual; assembly notation
CLINIT - CLREAD: no format line in the manual; assembly notation
CLREAD - DDIRT: no format line in the manual; assembly notation
DDIRT - RHOLE:
BY RHOLE (<hole/r/by/I1>,<string/w/by/I2>) - WHOLE:
BY WHOLE <string/r/by/I1>, <hole/w/by/I2> - SEND:
W1 SEND <hole number/r/W> - RECVE:
W1 RECVE <hole number/r/W>,<number of bytes/w/W> - SREGBL:
SREGBL {mask/r/W}, {address/r/W} - LREGBL:
LREGBL <mask/r/W>, <address/r/W> - SCNTXT:
SCNTXT <mask/r/W>, <address/r/W> - LCNTXT:
LCNTXT <mask/r/W>,<address/r/W>,<process number/r/W> - REXT:
Wn REXT <device/r/W> - WEXT:
Wn WEXT <device/r/W> - TOSSP:
TOSSP := <operand/r/W> - RPHS:
RPHS <domain number/r/W> - WPHS:
WPHS <domain number/r/W> - CAD:
CAD := <operand/r/W> - JUMPS:
JUMPS <address/r/W> - SVERS:
SVERS <destination/w/w> - SCPUNO:
SCPUNO <destination/w> - PHYLADR:
tn PHYLADR <operand/aa/W>
Notes
- The manual's hex code column has misprints in places (could be OCR errors): FFCOH for AMODB (letter O; the octal column gives 0xFFC0), FF7CCH for SCPUNO (the octal column, 177774B, gives 0xFFFC), and WEXT without the trailing H. The octal column is used here.
- The manual names some instructions differently in its contents list and code table than in the section headings: SNCTX and LNCTX for SCNTXT and LCNTXT, NPLC for NCPLC, RECV for RECVE. The section headings are used here.
- "Not stated" in the Privileged column means the manual's entry has no "Privileged instruction" line. It does not mean the instruction is allowed in user mode. LREGBL is a special case: the manual says that in non-privileged mode it cannot change ST2, PS, CED, CAD, CTE, MTE and TEMM.
- DDIRT is given as 0xFFFA by the manual. The assembler tables that came from the NDIX-C assembler have it at 0xFE1E, and the ND-5000 microcode maps both to the same routine (DCDUMP).
- On the ND-5000 microcode used for study (MICRO-5800-B30) there is no routine for RHOLE, and the opcode of AMODB leads to the illegal-instruction stub.
- PLCCN takes two operands in the manual. The June 1986 PLANC-500 assembler (version G) accepted it only with exactly three operands (measured by assembling test lines). Which is right for the ND-5000 is not settled.
Source
ND-500 Reference Manual ND-05.009.4, June 1987 edition; full manual text per instruction: https://retrocorelabs.github.io/nd500x/docs/ND5000-87-EXTENSION-INSTRUCTIONS/