ND110324: Difference between revisions

From NDWiki
Jump to navigation Jump to search
(Initial page)
 
(Added a reference and some data)
Line 6: Line 6:
* Interface : SCSI HVD (5V differential)
* Interface : SCSI HVD (5V differential)
* Rack mounted, vertical orientation
* Rack mounted, vertical orientation
* Weight approximately 70 kg
* Weight 58 kg
* Tape formats 1600 / 6250 BPI <ref>[http://www.sintran.com/sintran/library/libhw/libhw.html Norsk Data Library, Hardware] - [http://sintran.com/norsk-data/library/libquick/ND-99119-1-EN.pdf ND-99.119.1EN] : ND-110324 Magtape Quick reference card</ref>, selectable manually or via software
* Tape formats 1600 / 6250 BPI <ref>[http://www.sintran.com/sintran/library/libhw/libhw.html Norsk Data Library, Hardware] - [http://sintran.com/norsk-data/library/libquick/ND-99119-1-EN.pdf ND-99.119.1EN] : ND-110324 Magtape Quick reference card</ref>, selectable manually or via software
* Auto load function but possible to load manually too
* Auto load function but possible to load manually too


==Fault codes==
The drive have a lot of tests done during operation and can display a hexadecimal fault code on it's built in display. From 001 up to F13. For the complete list of fault codes, look in the FCD (Fault Code Dictionary) manual. <ref>[http://bitsavers.trailing-edge.com/pdf/stc/2920/|STC 2920 documents on Bitsavers]</ref>
Depending on interface and microcode version different fault codes can be displayed.
==Microcode level==
The drive can have several versions of microcode. To find the version of a drive, use the following front panel sequence.
<ENTER ADDR>,1FFA,<ENTER> : displays msb of the release level
                  <ENTER> : displays lsb of the release level
==Configuration==
There are a number of options that can be configured by switches on the interface card.
(See chapter 6.1.8 in the service manual from Apr88<ref>[http://bitsavers.trailing-edge.com/pdf/stc/2920/95521_STC_2920_Maintenance_Apr88.pdf 95521 STC 2920 Maintenance Apr88]</ref>)
* SCSI Bus ID
* Enable SCSI Bus Parity
* Connect TERMPWR to Pin 25
* Connect TERMPWR to Pin 26
* Enable DIFFSENS
* Disable Timeouts
* Report EOM.on Read
* Disable GCR Write Correction
* Write Buffer Threshold
* Read Buffer Threshold
* Number of Write Retries
* Number of Read Retries
* Buffer Size After Early EOT
* Sync on 2 Filemarks
==Sources==
==Sources==
<references/>
<references/>


[[Category:Norsk Data hardware]]
[[Category:Norsk Data hardware]]

Revision as of 13:50, 3 July 2016

The ND110324 is a re-branded StorageTek model 2920 9-track tape drive.

Technical data

  • Interface : SCSI HVD (5V differential)
  • Rack mounted, vertical orientation
  • Weight 58 kg
  • Tape formats 1600 / 6250 BPI [1], selectable manually or via software
  • Auto load function but possible to load manually too

Fault codes

The drive have a lot of tests done during operation and can display a hexadecimal fault code on it's built in display. From 001 up to F13. For the complete list of fault codes, look in the FCD (Fault Code Dictionary) manual. [2] Depending on interface and microcode version different fault codes can be displayed.

Microcode level

The drive can have several versions of microcode. To find the version of a drive, use the following front panel sequence.

<ENTER ADDR>,1FFA,<ENTER> : displays msb of the release level
                  <ENTER> : displays lsb of the release level

Configuration

There are a number of options that can be configured by switches on the interface card. (See chapter 6.1.8 in the service manual from Apr88[3])

  • SCSI Bus ID
  • Enable SCSI Bus Parity
  • Connect TERMPWR to Pin 25
  • Connect TERMPWR to Pin 26
  • Enable DIFFSENS
  • Disable Timeouts
  • Report EOM.on Read
  • Disable GCR Write Correction
  • Write Buffer Threshold
  • Read Buffer Threshold
  • Number of Write Retries
  • Number of Read Retries
  • Buffer Size After Early EOT
  • Sync on 2 Filemarks

Sources