Search results

Jump to navigation Jump to search
  • The instruction is used for monitor calls. A "monitor call" ... Some monitor calls will cause the program counter to be incremented ...
    2 KB (374 words) - 13:31, 7 August 2010
  • operate on data through commands and monitor calls. When a file system command ... of data is taken care of by appropriate calls to the I/O system from the ...
    952 bytes (132 words) - 09:04, 16 October 2017
  • #These parameter can be set and read by two monitor calls PASET (56 ... PAGET (monitor call) PASET (monitor call) == References == ...
    886 bytes (124 words) - 09:26, 12 September 2017
  • == Monitor Calls == The following seven monitor calls are implemented in SINTRAN III in ...
    6 KB (767 words) - 21:50, 23 July 2014
  • *1 = set binary mode. Subsequent INBT monitor calls will return a ... IOSET (monitor call) == References == 60.050.06 section 3.3.13 ...
    1 KB (169 words) - 23:43, 8 March 2014
  • in general is the list of so-called monitor calls (MON). The MON instruction is equivalent to the INT instruction found in Intel CPUs. However ...
    4 KB (667 words) - 14:20, 21 March 2018
  • Modified monitor calls: BRKM (MON 4), FIXC5 (MON 61), ABSTR (MON 131 ... COMMUNICATION, STOP-COMMUNICATION. New monitor calls: RSREC (MON 340), SGMTY ...
    9 KB (1,163 words) - 10:46, 15 November 2021
  • system, and a direct task cannot use monitor calls, files or other facilities ... should be fixed in memory by using the monitor call FIX or FIXC. Finally ...
    4 KB (712 words) - 12:44, 2 October 2017
  • handle as monitor call () else handle as any other illegal instruction ... it as a MON instruction (1530008), i.e. a monitor call (within the allowed ...
    3 KB (493 words) - 07:45, 26 May 2016
  • I/O must be performed via monitor calls as when writing MAC directly. ==Example code== The registers of the CPU were available in NORD PL as predefined ...
    3 KB (492 words) - 18:53, 4 April 2020
  • IOT SKA (opcode 161000) is the equivalent of MONitor calls for the range 0-127 (MON 0 .. MON 177). == Sources == * 06.014|(ND-06.014.02 rev A) ...
    4 KB (413 words) - 21:46, 18 May 2019
  • * ND-60.228.1 EN : SINTRAN III Monitor Calls (11 ex.) * [http://www ... * ND-860228.2 EN : SNTRAN III Monitor Calls * ND-860252.2 EN : SPRINT ...
    56 KB (6,932 words) - 08:40, 13 October 2022
  • supervisor. How to do file access and monitor calls is also included. Chapter ... ==== ND-60.228 SINTRAN III Monitor Calls manual ==== This manual describes ...
    60 KB (7,524 words) - 19:50, 4 February 2021
  • ==== NORD-1 All Core Monitor - Users Manual ==== Availability : ... The NCR 5386 SCSI controller chip, IOX instructions, and monitor calls ...
    47 KB (6,271 words) - 15:33, 10 July 2020