Search results

Jump to navigation Jump to search
  • The ND-5000 CPUs came in 3 types. Type 1 had two layers of cards, ... The difference in performance between models was mainly devised by ...
    11 KB (1,557 words) - 11:48, 5 November 2023
  • |Description=Multiply index by 3 |Format=MIX3 |Code=143 200 |Affected=X:=(A-1)*3 |Architecture=ND-100, ND-110 }} MIX3 is an assembly ...
    452 bytes (56 words) - 08:47, 21 March 2013
  • Source register (abbr. ) is encoded in bits 5..3 of Register Operation ... | SB || B register || 3 || 308 |- | SL || L register || 4 || 408 ...
    947 bytes (126 words) - 15:54, 26 July 2010
  • 3 0 0 A register = 1 X register = 1 T register = 0x0003 (bit 15 = 0, length field = 3) Memory area after ...
    2 KB (336 words) - 13:19, 26 July 2010
  • | DB || B register || 3 || 38 |- | DL || L register || 4 || 48 ... 06.014.02|Page 3-37 * 06.029.01|Pages 39-40 Category:ND-100 instructions ...
    1 KB (135 words) - 08:29, 14 February 2019
  • LDF is also used as a generic 3-word load function, and applications ... 06.014.02|Page 3-20 * 06.029.01|Page 60 * 60.096.01|Appendix E ...
    1 KB (172 words) - 14:29, 30 June 2010
  • #See rules 3 and 4 of @CHANGE-PASSWORD. Example: @REMOTE-PASSWORD 3, DELTA Files are only opened in the remote computer ...
    823 bytes (117 words) - 11:10, 31 July 2017
  • *3 - minutes *4 - hours Rules: #Permitted for all users. ... @HOLD 5, 3 @ The last @ is prompted after 5 minutes. == Related commands == ...
    746 bytes (98 words) - 23:48, 8 March 2014
  • For more see the list of 2 digit, 3 digit and 4 digit product codes. ... * ND-5900/3 * ND-5900/4 * ND-Butterfly workstation 40.012 ...
    14 KB (1,874 words) - 17:29, 3 April 2023
  • *ND-5900-2, ND-5900-3, and ND-5900-4, dual-, triple- and quad-CPU 5000 series machines. ==Software== In addition to hardware, Norsk Data also ...
    9 KB (1,360 words) - 11:05, 5 October 2017
  • ; : See rule 3 below. Rules: #Permitted only for user SYSTEM. #The subcommands must follow the rules given in @LOOK-AT, rule 3. ...
    692 bytes (82 words) - 13:26, 28 September 2017
  • ; : (decimal 0-3, default = 0) the page table to be used for the routine. ... @ENTSG 42,3,9,30000 The routine on segment 42 will be entered to run ...
    1 KB (149 words) - 22:26, 21 December 2013
  • **TH3:0, TH2:0, TH1:0-3 - upper limit display: 020 - memory address ... **TH3:0, TH2:0, TH1:0-3 - upper limit display: 030 - memory address ...
    2 KB (274 words) - 17:39, 14 January 2018
  • The card has three thumbwheel switches numbered 3,2,1 from the top ... **3 - 1.2 K baud **6 - 9.6 K baud **7 - 38.4 K baud **8 - 153.6 K baud ...
    2 KB (327 words) - 16:56, 3 April 2023
  • Test programs No. 3 for ND-10, ND-12 and ND-100. redundant == Known versions == * ND-10326B * ND-10326C Category:Norsk Data software ...
    179 bytes (22 words) - 14:07, 2 January 2017
  • ; : (default type = DATA) for version (v) see rule 3 of @CREATE-NEW ... Version 2 of the contiguous file FILE-3 is created and allocated at ...
    971 bytes (131 words) - 14:00, 14 November 2017
  • * Current loop / RS-2323 selection, group A, 3-4 * Current loop / RS ... * Current loop / RS-2323 selection, group B, 3-4 Extended address selection ...
    1 KB (184 words) - 19:07, 14 January 2018
  • 3 Paper tape punch 4 Card reader 5 Line printer If one of the specified ... @SCHEDULE 2, 3, 4, 5 The batch job reserved logical device numbers ...
    2 KB (251 words) - 14:07, 14 November 2017
  • *LED 3 - yellow - parity *LED 4 - yellow - compare *LED 5 - yellow - active ... **2 - device address 520-527 (octal) - ident code 3 (octal) - reserved ...
    2 KB (238 words) - 17:42, 14 January 2018
  • unit (normally 20 milliseconds), 2 = seconds, 3 = minutes, 4 = hours. ... @SET KLOKK 5,3 The RT program KLOKK will be set up for execution in ...
    1 KB (165 words) - 08:34, 21 August 2017

View (previous 20 | next 20) (20 | 50 | 100 | 250 | 500)