3202: Difference between revisions

From NDWiki
Jump to navigation Jump to search
(→‎ECO: add 100-752)
(→‎ECO: add 100-763)
Line 37: Line 37:
* ECO 100-751 - Gives false interrupt, IOX error, MOR or Protect violation<ref name="ECO"></ref>
* ECO 100-751 - Gives false interrupt, IOX error, MOR or Protect violation<ref name="ECO"></ref>
* ECO 100-752 - Sintran corruption when heavy load on the bus<ref name="ECO"></ref>
* ECO 100-752 - Sintran corruption when heavy load on the bus<ref name="ECO"></ref>
* ECO 100-763 - Sintran hangs or gives ILLEGAL INSTRUCTION.<ref name="ECO"></ref>
* ECO 100-774 - Memory out of range<ref name="ECO">sintran.com, Norsk Data library, ECO [http://sintran.com/sintran/library/libeco/libeco.html]</ref>
* ECO 100-774 - Memory out of range<ref name="ECO">sintran.com, Norsk Data library, ECO [http://sintran.com/sintran/library/libeco/libeco.html]</ref>
* ECO 100-779 - System failing with cache enabled<ref name="ECO"></ref>
* ECO 100-779 - System failing with cache enabled<ref name="ECO"></ref>

Revision as of 17:37, 3 April 2023

ND 120 CPU board, component side.
ND 120 CPU board, solder side.

3202 is the ND-120/CX CPU board. The same identifier (variants 350175/350176/350177/350178) is used for ND-125/CX CPU boards. The difference is that the 125/CX has faster on-board memory access and includes more on-board memory (8/12/16 MB, the 120/CX can have up to 6MB RAM on-board).[1]

Introduction

It contains the CPU, bus arbitration logic, memory control, memory and other subsystems. It also has the Real time clock and the I/O for the serial console.

Switches and indicators

  • SW3 - Master Clear - normal position = central. This switch may be depressed to give a hardware master clear to the CPU.
  • TH1 - ALD select
  • TH2 - Baud rate select
  • LED3 - self test passed (green)
  • LED2 - self test fail (red)
  • LED1 - cache OFF (red)
  • SW1 - Cache ON, normal position = down.
  • LED6 - CPU grant (green)
  • LED7 - bus grant (yellow)
  • SW2 - Memory OFF, normal position = down.
  • LED4 - parity error (red)
  • LED5 - parity disable (red)
  • SW4 - Parity disable, normal position = down.
  • upper limit display
    • 000 - memory off (SW2)
    • 100 - 2M Bytes onboard memory
    • 200 - 4M Bytes onboard memory
    • 300 - 6M Bytes onboard memory

Connectors

The A and B connectors are used for I/O, the C connector is used for the ND-100 Bus.

I/O Devices on the card

none?

ECO

ECO or Engineering Change Order is a hardware change. Here is a list of known ECO's for this card.

  • ECO 100-751 - Gives false interrupt, IOX error, MOR or Protect violation[2]
  • ECO 100-752 - Sintran corruption when heavy load on the bus[2]
  • ECO 100-763 - Sintran hangs or gives ILLEGAL INSTRUCTION.[2]
  • ECO 100-774 - Memory out of range[2]
  • ECO 100-779 - System failing with cache enabled[2]
  • ECO 100-785 - Memory out of range, IOX-error[2]
  • ECO 100-786 - Upgrade ND-120CX CPU & MM 32B 2MB to ND-125CX[2]
  • ECO X01 - New backup battery for the calendar on ND-120 CPU[2]

Reference